RENTAL: Aquadopp Current Profiler 1MHz

Small and compact, with up to 25 m current profiling range, the Aquadopp Profiler is a highly versatile Acoustic Doppler Current Profiler (ADCP)

Category: Tag:

The Aquadopp Profiler is a highly versatile Acoustic Doppler Current Profiler (ADCP). The 1 MHz version has a current profiling range of up to 25 m. Designed for simple yet powerful operation, this current profiler is packed with features used by engineers and researchers to enable accurate and effective hydrodynamic data collection in a variety of environmental conditions.

  • – Up to 25 m current profiling range
  • – Right-angle head orientation
  • – PUV wave measurements

Applications

  • – Mean flow measurements with high focus on ease of use and simplicity
  • – Measurements in flow regimes with strong variations in flow speeds
  • – Projects with needs for both high-resolution and normal-range current measurements
  • – Studies of deep-water currents
  • – Studies of tidal currents
  • – Measurements of combinations of waves and currents
  • – Suitable for wave buoys
  • – This instrument is used to perform river discharge measurements by River Insight.

Water velocity measurements

Maximum profiling range12-25 m
Cell size0.3-4 m
Minimum blanking0.20 m
Maximum number of cells96
Measurement cell positionN/A
Default position (along beam)N/A
Velocity range±10 m/s
Accuracy±1% of measured value ±0.5 cm/s
Velocity precisionConsult instrument software
Maximum sampling rate (output)1 Hz
Internal sampling rate7 Hz

Echo intensity (along slanted beams)

SamplingSame as velocity
Resolution0.45 dB
Dynamic range90 dB
Transducer acoustic frequency1 MHz
Number of beams3
Beam width3.4°

Sensors

Temperature:Thermistor embedded in head
Temp. range-4 to +40 °C
Temp. accuracy/resolution0.1 °C/0.01 °C
Temp. time response10 min
Compass:Magnetometer
Accuracy/resolution2°/0.1° for tilt < 20°
Tilt:Liquid level
Accuracy/resolution0.2°/0.1°
Maximum tilt30°
Up or DownAutomatic detect
Pressure:Piezoresistive
Range0-100 m (inquire for options)
Accuracy/precision0.5% FS / 0.005% of full scale

Analog inputs

No. of channels2
Supply voltage to analog output devicesThree options selectable through firmware commands: 1) Battery voltage/500 mA, 2) +5 V/250 mA, 3) +12 V/100 mA
Voltage input0-5 V
Resolution16 bit A/D

Data recording

Capacity9 MB, can add 4/16 GB
Data record9*Ncells + 32 bytes
Diagnostics recordN/A
Wave recordNsamples * 24 + 60 bytes
ModeStop when full (default) or wrap mode

Real-time clock

Accuracy±1 min/year
Backup in absence of power4 weeks

Data communications

I/ORS-232 or RS-422
Communication baud rate300-115200 Bd
Recorder download baud rate600/1200 kBd for both RS-232 and RS-422
User controlHandled via “Aquadopp” software, ActiveX®function calls, or direct commands with binary or ASCII data output

Connectors

BulkheadMCBH-8-FS
CablePMCIL-8-MP on 10 m Polyurethane cable

Software

FunctionsDeployment planning, instrument configuration, data retrieval and conversion (for Windows®)

Power

DC input9-15 V DC
Maximum peak current3 A
Avg. power consumption0.05 W
Sleep current< 100 μA
Transmit power0.3-20 W, 4 adjustable levels

Batteries

Battery capacity1) 50 Wh (alkaline or Li-ion), 2) 165 Wh (lithium), 3) Single or dual
New battery voltage13.5 V DC (alkaline)

Environmental

Operating temperature-5 to +40 °C
Storage temperature-20 to +60 °C
Shock and vibrationIEC 721-3-7
EMC approvalIEC 61000
Depth rating300 m (3000 m option)

Materials

Standard modelPOM and polyurethane plastics with titanium fasteners

Dimensions

Maximum diameter75 mm
Maximum length~550 mm (single battery), +110 mm (double battery) depending on head configuration

Weight

Weight in air2.2 kg
Weight in water0.2 kg
More information from Nortek